传统铁箍墩接法加固底部糟朽木柱轴压试验
DOI:
作者:
作者单位:

(1.大同大学历史与旅游文化学院,山西大同 037009;2.故宫博物院,北京 100009;3.北京交通大学土木建筑工程学院,北京 100044;4.北京工业大学工程抗震与结构诊治北京市重点实验室,北京 100124)

作者简介:

周 乾(1975—),男,博士后,研究馆员,研究方向:文物建筑抗震加固与振动控制,Email:qianzhou627@126.com

通讯作者:

中图分类号:

基金项目:

国家自然科学基金优秀青年项目资助(51422801),国家自然科学基金项目资助(51178028),北京自然科学基金重点项目资助(8151003),上海市工程结构安全重点实验室开放课题(2016-KF05)


Axial experiments on timber columns strengthened on decay bases by iron band wrapping of traditional Dunjie method
Author:
Affiliation:

(1. School of Culture of History and Tourism, Datong University, Datong 037009, China;2. Palace Museum, Beijing 100009, China;3. School of Civil Engineering, Beijing Jiaotong University, Beijing 100044, China;4. Beijing Key Laboratory of Earthquake Engineering and Structural Retrofit, Beijing University of Technology, Beijing 100124,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 文章评论
    摘要:

    铁箍墩接是古建木柱柱根糟朽的一种传统加固方法。为探讨该方法的有效性,以故宫内某古建木柱为例,进行了试验研究。制作了1根完好木柱、3根铁箍墩接法加固木柱,开展了轴压试验,获得了木柱加固前后的承载力-变形曲线,以及延性、应变、刚度等参数,讨论了铁箍墩接法的加固机理。结果表明:传统铁箍法加固底部糟朽木柱后,由于铁箍对木柱的侧向约束作用,木柱的极限承载力可恢复约91.8%,延性性能可恢复约95.2%,水平极限应变恢复率约97.2%,竖向极限应变恢复率约84.1%,且加固木柱的刚度要大于完好木柱。由于铁箍材料与木材强度差别较大,使得加固后木柱的整体性能要低于完好木柱,因而加固效果有限。结果可为古建筑木结构的保护与维修提供理论参考。

    Abstract:

    Traditionally,decayed ancient timber columns are stabilized using the “Dunjie” method, which involves wrapping the column with iron bands. To test the validity of the method, a timber column from an ancient building in the Forbidden City was selected as example for research. Four models were built, some of which had decayed bottoms, and were strengthened by iron bands according to the Dunjie method. Axial compression tests were carried out. Parameters such as forcedisplacement curves, ductility, strain and vertical stiffness of the models were obtained to test the results.The mechanism of strengthening by the Dunjie method was also considered. The results show that the ultimate compression strength of the strengthened columns can be restored to about 91.8% that of the undecayed column, their ductility can be restored to about 95.2%, and their compressive strain can be restored to about 97.2% in horizontal direction and 84.1% in vertical direction. The vertical stiffness values of the strengthened columns are larger than that of the unreinforced, undecayed column. So far as integrity is concerned, the strengthened columns are not as good as the undecayed column because of the difference in strength between iron and timber. Thus the strengthening capability of the traditional Dunjie method is limited.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-10-27
  • 最后修改日期:2016-03-02
  • 录用日期:
  • 在线发布日期: 2017-10-25
  • 出版日期:
您是第位访问者
主办单位:上海博物馆 编辑出版:《文物保护与考古科学》编辑委员会
地址:上海市徐汇区龙吴路1118号,上海博物馆文物保护科技中心,《文物保护与考古科学》编辑部
电话:021-54362886 传真:021-54363740 E-mail:wwbhykgkx@163.com
文物保护与考古科学 ® 2024 版权所有
沪ICP备10003390号-3
沪公网安备 31010102005301号