聚合物膜修饰电极QCM方法对博物馆环境中典型气态分子污染物甲醛的检测研究
DOI:
作者:
作者单位:

(馆藏文物保存环境国家文物局重点科研基地,上海博物馆, 上海 200050) 闫 莹,赵利红,彭熙瑜,蔡兰坤 (华东理工大学, 上海 200237)

作者简介:

周 浩(1970—),男,副研究馆员,上海博物馆文物保护与考古科学实验室,研究方向:金属文物保护,馆藏文物保存环境研究,E mail:haoshm1970@163.com

通讯作者:

中图分类号:

基金项目:

国家科技支撑计划资助(2006BAK20B01)


Research on detection of formaldehyde,a typical gas pollutant in museum environments,using a quartz crystal microbalance
Author:
Affiliation:

(Key Scientific Research Base of the Museum Environment,State Administration for Cultural Heritage,Shanghai Museum,Shanghai 200050,China) YAN Ying,ZHAO Li hong,PENG Xi yu,CAI Lan kun (School of Resources & Environmental Engineering,East China University of Science & Technology,Shanghai 200237,China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 文章评论
    摘要:

    在可以导致文物、艺术品及历史档案资料品质退化的几种环境因素中,浓度较低的气态悬浮分子污染物甲醛对文物是最具潜在破坏性影响。在光、热等物理因素的联合作用下,其形成的复合污染对文物的破坏作用更强,而就其对不同种类文物的影响的规律性研究目前尚缺少基础数据。因此,本研究采用聚苯胺膜修饰的石英晶振片电极(简称复合电极),结合石英晶体微天平(QCM)方法,对微环境中不同浓度的甲醛进行了检测研究。研究结果表明,复合电极对甲醛有较好的响应信号,复合电极频率变化值与时间基本呈线性关系,并且随甲醛浓度的升高,复合电极频率下降速度增加,频率变化值增大。研究还发现,甲醛的浓度值与频率变化值也呈现出较好的线性关系。据此可以推算文物保存环境中挥发性气态分子污染物甲醛的含量。本方法可以对文物保存环境中甲醛浓度的变化进行实时监测,为文物保存环境质量评价提供一种新的方法和依据。

    Abstract:

    Among environmental issues affecting cultural relics,art objects and documentation materials,low concentrations of the pollutant,formaldehyde,have a great potential for causing damage.In the presence of light and heat,formaldehyde may form complex substances which may cause even more damage.There is little research on the effect of formaldehyde on different categories of cultural relics.In the present study,different concentration of formaldehyde in micro environments were tested using a quartz crystal film electrode (the composite electrode) modified with polyaniline in conjunction with a quartz crystal microbalance (QCM).The results showed the composite electrode responds well to the formaldehyde.The frequency change of the composite electrode shows a direct relationship with time. Moreover,as the concentration of formaldehyde increases,the change in frequency of the composite electrode and the speed decreases.The study also indicates that there is a linear correlation between the concentration of formaldehyde and change in frequency of the composite electrode.Therefore,the concentration of formaldehyde could be deduced from experimental results.This method provides a means for real time monitoring of the concentration of formaldehyde and represents way to evaluate the storage environment of cultural relics.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2009-07-27
  • 最后修改日期:2009-12-03
  • 录用日期:
  • 在线发布日期: 2019-07-16
  • 出版日期:
您是第位访问者
主办单位:上海博物馆 编辑出版:《文物保护与考古科学》编辑委员会
地址:上海市徐汇区龙吴路1118号,上海博物馆文物保护科技中心,《文物保护与考古科学》编辑部
电话:021-54362886 传真:021-54363740 E-mail:wwbhykgkx@163.com
文物保护与考古科学 ® 2024 版权所有
沪ICP备10003390号-3
沪公网安备 31010102005301号