氯离子选择性电极测定铁器碱性脱盐溶液中 氯离子的含量
DOI:
作者:
作者单位:

作者简介:

成小林(1975-),女,硕士,馆员,2001年毕业于北京大学考占与文博学院,E - mail:xiaoshanxs@ sina.Com

通讯作者:

中图分类号:

基金项目:

国家科技支撑计划资助(2006BAK20803)


Measuring chloride ion concentration in alkaline solutions by chloride specific ion electrode during treatment of corroded iron objects
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 文章评论
    摘要:

    在铁质文物的保护过程中,脱盐是重要的保护程序之一。通常铁器的脱盐溶液为碱性。本工作主要研究氯 离子选择性电极法在测定碱性脱盐溶液中的氯离子含量时,溶液pH值和复配溶液中的表面活性剂对测定结果的 影响。实验结果表明:(1)用氯离子选择性电极法测定碱性脱盐溶液或复配碱性脱盐溶液中的氯离子浓度是可行 的;(2)溶液的pH值对测量结果有一定的影响,当溶液pH值在2-7范围内时,其对电位值影响不大;(3)表面活 性剂对测量结果影响较小,在实际应用中,应配制与待测溶液组分相同的氯离子标准溶液,后期数据处理并绘制标 准曲线,以使测量结果尽可能接近实际值。精密度和回收率实验表明,该方法准确度满足定量务析的要求。由此 可见,当脱盐溶液为碱性NaOH或复配碱性NaOH溶液时,用氯离子选择性电极实时监测脱盐溶液中的氯离子含量 能较好地反映器物脱盐程度。

    Abstract:

    In conservation of iron cultural relics , desalination is one of very important treatment. Generally , the de- salination solution is alkaline. In this study , the influence of various factors , such as pH value ,in alkaline desalina- tion solutions,on the chloride specific ion electrode were examined. These experiments showed that the pH value of the desalination solution affects the potential of chloride specific ion electrode , especially when the chloride ion con- centration is low. The optimal pH of the solution is between 2 and 7. The surfactant in the solution had no significant impact on the chloride specific ion electrode ,as seen in the fact that the potential value of the l# chloride standard solution( 0. 5 mol/L NaOH + 1. 5% DP - 105 ) was equal of that of 2# solution (0. 5 mol/L NaOH) . However, bothof them were higher than the potential value of 3# solution ( aqueous solution) . In practice , the components of chlo- ride ion standard solution should be the same as that of the solution to be tested. Using chloride ion standard solu- tions ,it was showed that when chloride ion concentration is between o and 200 mg/L , the standard curve was highly linear , reproducible , and precise , and had a high correlation coefficient.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2009-06-15
  • 最后修改日期:2009-09-27
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
您是第位访问者
主办单位:上海博物馆 编辑出版:《文物保护与考古科学》编辑委员会
地址:上海市徐汇区龙吴路1118号,上海博物馆文物保护科技中心,《文物保护与考古科学》编辑部
电话:021-54362886 传真:021-54363740 E-mail:wwbhykgkx@163.com
文物保护与考古科学 ® 2024 版权所有
沪ICP备10003390号-3
沪公网安备 31010102005301号
关闭